04th December 2010

Item Description:

Brand: Blue Ocean

Type/number of model: Model number is BOA025. UK.RB. Barcode - 4020628997304.

Description: Balance board stand which includes a power supply. The risk is posed by the power supply only.

Country of origin: China

Attached Images: (click to enlarge)

Photo of the Balance board stand - Wii Balance Board Stand (image 1 of 2) Photo of the Balance board stand - Wii Balance Board Stand (image 2 of 2)

Danger:

Electric shock

The power supply poses a risk of electric shock because the connection to the live and neutral pins of the plug is made purely by solder. In the event of the solder failing on one of the pins a short circuit could occur. There is excess wire on the low voltage side of the transformer; if one of these wires were to become loose they could touch the input side of the board. In addition, the transformer does not provide sufficient insulation between the primary and secondary circuits. The plug face and pin sizes are considered to be too small.
The product does not comply with the Low Voltage Directive (LVD) and with the relevant European standard EN 60950.

Action Taken:

Voluntary withdrawal from the market and recall from consumers.

Notifying Country:

UNITED KINGDOM

The Next Step...